• Login
5 Year Warranty

EKI-1242IPNMS-A Modbus to PROFINET Gateway with Wide Temp.

  • Seamless integrate Modbus RTU/TCP and PROFINET communication
  • Built-in real time diagnostic to increase highly efficiency of device management
  • Modbus TCP Master mode supports 64 connections
  • Designed for protocol extensibility and adaption
  • Supports dual power input for power redundancy
  • Mounts on DIN-rail and Wall mount

Add to Cart Buy Now

More Description

PROFINET Fieldbus gateways provide seamless communication between Fieldbus and Industrial Ethernet and allow different protocol devices to communicate with each other. They are designed for reliable protocol extensibility and seamless integration with existing network devices. They offer a viable solution for efficiently converting data from devices with different protocols and reduce the possibility of expensive device purchases or software programming errors.

Extended Specifications

Power

  • Power Consumption 5.2W (system)
  • Power Input (DC) 12 ~ 48 VDC
  • Power Connector Type Terminal block
  • Power Operating Current 0.22@24V ;  0.11@48V
  • Redundant Dual Inputs 50 bps ~ 921.6 kbps, any baud rate setting

Protection

  • Reverse Polarity Present
  • Port to Port Isolation Built-in 1.5 KV magnetic isolation

Serial Communication

  • Serial Port Number 2
  • Data Bits 7, 8
  • Stop Bits 1, 2
  • Parity None, Odd, Even, Space, Mark
  • Serial Signals RS-232: TxD, RxD, CTS, RTS, DTR, DSR, DCD, RI, GND
  • RS-232 Yes
  • RS-422 Yes
  • RS-485 Yes
  • Serial Port Connector Type DB9 male
  • Serial Transmission Speed 50~ 921.6 kbps, any baud rate setting
  • Flow Control XON/XOFF, RTS/CTS, DTR/DSR

Software

  • Modbus RTU/TCP Mode Master
  • Modbus RTU/TCP Functions Support 1, 2, 3, 4, 5, 6, 15, 16, 23
  • Modbus RTU/TCP Max. No. of Connections 64 connections
  • PROFINET Type Slave
  • PROFINET Slot 64
  • PROFINET Cyclic Data Exchange 64 ms cycle time

Environment

  • Temperature (Storage Range) -40 ~ 85°C (-40 ~ 185°F)
  • Humidity (Operating Range) 10 ~ 90% RH non-condensing (refer to IEC 60068-2-3)
  • Temperature (Operating Range) -40 ~ 75° C (-40 ~ 167° F)
  • Temperature (Min. Operating) -40° C (-40° F)
  • Temperature (Max. Operating) 75° C (167° F)

Mechanism

  • Enclosure (Metal) Metal with solid mounting hardware
  • Dimensions (W x H x D) 42 x 140 x 95 mm (1.66" x 5.52" x 3.75")
  • IP Rating IP30
  • Weight 0.497
  • Mounting (DIN-rail) Yes
  • Mounting (Wall) Yes

Ethernet Communication

  • RJ45 Transmission Speed 10/100BaseT(X), Auto-sensing
  • Ethernet Port Number 4
  • RJ45 Port Connector Type RJ45
  • Ethernet Standard IEEE 802.3 , 802.3ab , 802.3u

Certification

  • EMC CE, FCC Part 15 Subpart B (Class A)
  • EMI EN 55011/ EN 55022 Class A, EN 61000-6-4, FCC Part 15 Subpart B Class A
  • EMS EN 61000-4-2 (Level 4), EN 61000-4-3 (Level 3), EN 61000-4-4 (Level 4), EN 61000-4-5 (Level 4), EN 61000-4-6 (Level 3), EN 61000-4-8 (Level 4)
  • Shock IEC 60068-2-27
  • Freefall IEC 60068-2-32
  • Vibration IEC 60068-2-6

Warranty

  • Warranty Period 5 years

Modbus Communication

  • Modbus RTU/TCP Max. Number of Connections 64 connections
  • Modbus RTU/TCP Functions Support 1,2,3,4,5,6,15,16,23
  • Modbus RTU/TCP Mode Master

Protocol Support

  • Modbus TCP Yes
  • Modbus RTU Yes
  • PROFINET Yes
  • Ethernet Yes
  • Modbus ASCII Yes
x
Office Locations

1-800-346-3119

Monday-Friday, 7am-5pm CST

Contact Advantech